<LOGO>
FM Transmitter Measurement Report
Created: 2025-07-22 08-51-26
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 4/5, 53 dBuV SANDELS
Pilot RDS Phase Difference
6.1 kHz 5.4 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
12 kHz 71 kHz 11517 1,4327
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,5 dBr 4,90 dBr 6,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 71 kHz MIN: 12 kHz % above 76 kHz: 1,4327 Acquired: 2025/07/22 8.50.23 Total samples: 11517 Equivalent time: 0:09:35 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 6,2 dBr MIN: 3,5 dBr AVE: 4,90 dBr % above 12,2 dBr: 0,0 Last value: 3,8 dBr (2025/07/22 8.50.22) 08.36 08.38 08.40 08.42 08.44 08.46 08.48 08.50 0 2 4 6 Pm [dBr]